Appendix A
A-2 MIL-4750/MIL-4755 Master/Slave Modules
S
P
E
C
I
F
I
C
A
T
I
O
N
S
A.4 Connectors
A.4.1 RS-232, RJ-45 Connector
Use a standard null-modem for communication when
connecting “straight-through” to a DB9 connector.
A.4.2 RJ-45 Pinouts
Pin 1: Transmit data +
Pin 2: Transmit data -
Pin 3: Receive data +
Pin 6: Receive data -
Note:
For a workstation/PC port, use a swap cable. Pins are connected: 1 to 3, 2 to 6, 3 to 1, and 6 to 2.
A.5 Environmental Operating Conditions
A.6 Power Supply
Both modules are powered via the backplane of the media
conversion system. The power consists of +5VDC +/-10%
@10A.
PIN Number Signal PIN Number Signal
1NC6 NC
2 RXD 7 RTS/DTR
3 TXD 8 CTS
4 DTR/RTS 9 (for DB9) NC
5 GND
Parameters Minimum Maximum
Operating Temperature +5° C 40° C
Humidity: Non-condensing 10% 95%
Altitude test NA 12,000 ft. (at 40° C)
Temperature test (Operating) 5° C 50° C
Temperature test (Packaged) -25° C 70° C